Product inquiry

* Note: Please fill in the information accurately to keep your phone open. We will contact you as soon as possible.

Maximum 5 files. Support jpg, jpeg, png, gif, txt, doc, pdf, xls, docx, xlsx, less than 5MB
Submission
  • Low-Smoke Zero-Halogen Cable
Low-Smoke Zero-Halogen Cable
+
  • Description
  • Rated Voltage: Typically 0.6/1kV, compliant with IEC 60502-1, GB/T 12706.1 and other international/national standards, suitable for low-voltage power transmission and distribution systems.Conductor Material: Available in copper or aluminum conductors. Copper conductors offer low resistivity (≤0.017241Ω·mm²/m at 20℃), excellent conductivity and corrosion resistance; aluminum conductors are cost-effective and lightweight, with resistivity (≤0.028264Ω·mm²/m at 20℃) meeting low-voltage transmission requirements.Insulation Material: Adopts cross-linked polyethylene (XLPE) or modified polyvinyl chloride (PVC) with halogen-free formula. It has high dielectric strength (≥20kV/mm), good insulation stability and low dielectric loss, effectively preventing leakage and short-circuit risks.

    Sheath Material: Halogen-free low-smoke flame-retardant material (such as halogen-free polyolefin), complying with GB/T 19666 and IEC 60754 standards. The oxygen index is ≥30%, achieving flame-retardant grade (usually Class B/C/D) as requiredCurrent-Carrying Capacity: Ranges from 10A to 630A depending on conductor cross-section (1.5mm² to 400mm²) and laying method (air, direct burial, cable trench). For example, the long-term allowable current-carrying capacity of a 3×120mm² copper conductor cable is about 280A (air laying, 40℃ ambient temperature).

    Operating Temperature: The maximum long-term operating temperature of the conductor is 90℃, the short-circuit (maximum 5 seconds) temperature does not exceed 250℃, and it can operate stably in the ambient temperature range of -40℃ to 70℃.

    Mechanical Performance: Tensile strength ≥12MPa, elongation at break ≥150%, good flexibility (bending radius ≥15 times the cable outer diameter), suitable for complex laying environments.

    Data Centers and Communication Facilities: Used for power distribution and connection lines of servers, switches and other equipment in data centers, computer rooms and communication base stations. It has low smoke and low toxicity, which can protect precision electronic equipment from smoke and corrosion, and ensure the continuous operation of the communication system.

  • Low-Smoke Zero-Halogen Cable
Low-Smoke Zero-Halogen Cable
+

Low-Smoke Zero-Halogen Cable

Typically 0.6/1kV, compliant with IEC 60502-1, GB/T 12706.1 and other international/national standards, suitable for low-voltage power transmission and distribution systems.

Telephone:

If you need customized products, Contact us!

  • Description
  • Rated Voltage: Typically 0.6/1kV, compliant with IEC 60502-1, GB/T 12706.1 and other international/national standards, suitable for low-voltage power transmission and distribution systems.Conductor Material: Available in copper or aluminum conductors. Copper conductors offer low resistivity (≤0.017241Ω·mm²/m at 20℃), excellent conductivity and corrosion resistance; aluminum conductors are cost-effective and lightweight, with resistivity (≤0.028264Ω·mm²/m at 20℃) meeting low-voltage transmission requirements.Insulation Material: Adopts cross-linked polyethylene (XLPE) or modified polyvinyl chloride (PVC) with halogen-free formula. It has high dielectric strength (≥20kV/mm), good insulation stability and low dielectric loss, effectively preventing leakage and short-circuit risks.

    Sheath Material: Halogen-free low-smoke flame-retardant material (such as halogen-free polyolefin), complying with GB/T 19666 and IEC 60754 standards. The oxygen index is ≥30%, achieving flame-retardant grade (usually Class B/C/D) as requiredCurrent-Carrying Capacity: Ranges from 10A to 630A depending on conductor cross-section (1.5mm² to 400mm²) and laying method (air, direct burial, cable trench). For example, the long-term allowable current-carrying capacity of a 3×120mm² copper conductor cable is about 280A (air laying, 40℃ ambient temperature).

    Operating Temperature: The maximum long-term operating temperature of the conductor is 90℃, the short-circuit (maximum 5 seconds) temperature does not exceed 250℃, and it can operate stably in the ambient temperature range of -40℃ to 70℃.

    Mechanical Performance: Tensile strength ≥12MPa, elongation at break ≥150%, good flexibility (bending radius ≥15 times the cable outer diameter), suitable for complex laying environments.

    Data Centers and Communication Facilities: Used for power distribution and connection lines of servers, switches and other equipment in data centers, computer rooms and communication base stations. It has low smoke and low toxicity, which can protect precision electronic equipment from smoke and corrosion, and ensure the continuous operation of the communication system.